EN
Air CompressorHumidifier

TCC60

TCC60 two-stage air compressor is designed for 60-90kW fuel cell system with air flow rate of 120g/s and pressure ratio of 2.7.The aerodynamic can be customize to match our customers' requirements.

TCC60

SPECIFICATION

ModelTCC60
Fuel cell system power range60~90 kW
Type Two-stage
Bearing typeAir foil bearing
Start- stop life>200000 cycles
Speed range20000~100000 rpm
Rated flow rate120 g/s
Rated pressure ratio2.7
Continuous motor power18 kW
HV250-450/450~750 VDC
LV9~36 VDC
Ambient temperature-30~75 ℃
Inlet temperature-30~45 ℃
Cooling air inlet temperature<90 ℃
Coolant mediumWater/Glycol 50/50%
Coolant flow rate≥6 L/min
IP gradeIP67/IP6K9K
size335*262*202 mm
Weight <10.5 kg

KEY FIELD

TCC60

TCC120

TCC120 two-stage air compressor is designed for 100-120kW fuel cell system with air flow rate of 150g/s and pressure ratio of 3.0.The aerodynamic can be customize to match our customers' requirements.

TCC120

SPECIFICATION

ModelTCC120
Fuel cell system power range100~120 kW
Type Two-stage
Bearing typeAir foil bearing
Start- stop life>200000 cycles
Speed range20000~95000 rpm
Rated flow rate150 g/s
Rated pressure ratio3.0
Continuous motor power25 kW
HV450~750 VDC
LV9~36 VDC
Ambient temperature-30~75 ℃
Inlet temperature-30~45 ℃
Cooling air inlet temperature<90 ℃
Coolant mediumWater/Glycol 50/50%
Coolant flow rate≥6 L/min
IP gradeIP67/IP6K9K
size398*283*208 mm
Weight <15.5 kg

KEY FIELD

TCC120

DO YOU NEED OUR HELP?